The new generation Novatronic XV

inhaltsbild

The advantages of the Novatronic XV at a glance:

  • Boiler class 5, EN 303-5:2012
  • Large filling capacity
  • Low filling edge / free cross-section when feeding from the top
  • Logs with a length of 56 cm to 109 cm
  • Large ash chamber
  • Optimum combustion with LC3 Lambda Control
  • Simple cleaning of the heat exchanger from the outside either manually or automatically
  • Heat-resistant step/vibration grate
  • High efficiency
  • Optional automatic ignition
  • Underpressure controlled combustion guarantees lowest possible emissions
  • EC flue gas fan for low noise level

Log firing system: Novatronic XV 30-50 kW

The Novatronic XV log combustion system is suitable for use in a single house or apartment block as well as large farmhouses.

Fuel: Wood logs
Novatronic XV 35: Wood logs 1/2 m

Boiler type Nominal capacity 
in kW.
Filling chamber 
in L.
Dimensions 
in mm.
Filling edge 
height in mm
Weight 
in kG
Novatronic XV 35/30 30 163 H: 1250 W: 875 D: 1253 972 930
Novatronic XV 35/35 35 163 H: 1250 W: 875 D: 1253 972 930
Novatronic XV 35/40 40 163 H: 1250 W: 875 D: 1253 972 930
Novatronic XV 35/49 49 163 H: 1250 W: 875 D: 1253 972 930
Novatronic XV 35/50 50 163 H: 1250 W: 875 D: 1253 972 930

Log firing system: Novatronic XV 35-55 kW

The Novatronic XV log combustion system is suitable for use in a single house or apartment block and agricultural applications.

Fuel: Wood logs
Novatronic XV 55: Wood logs 1/2 m

Boiler type Nominal capacity 
in kW.
Filling chamber 
in L.
Dimensions 
in mm.
Filling edge 
height in mm
Weight 
in kG
Novatronic XV 55/35 35 203 H: 1430 W: 875 D: 1253 1151 1045
Novatronic XV 55/45 45 203 H: 1430 W: 875 D: 1253 1151 1045
Novatronic XV 55/49 49 203 H: 1430 W: 875 D: 1253 1151 1045
Novatronic XV 55/55 55 203 H: 1430 W: 875 D: 1253 1151 1045

Log firing system: Novatronic XV 49-80kW

The Novatronic XV log combustion system is suitable for use in a single house or apartment block and agricultural applications.

Fuel: Wood log
Novatronic XV 80: Wood logs 1 m

Boiler type Nominal capacity 
in kW.
Filling chamber 
in L.
Dimensions 
in mm.
Filling edge 
height in mm
Weight 
in kG
Novatronic XV 80/49 49 319 H: 1345 W: 1405 D: 1116 1092 1480
Novatronic XV 80/50 50 319 H: 1345 W: 1405 D: 1116 1092 1480
Novatronic XV 80/60 60 319 H: 1345 W: 1405 D: 1116 1092 1480
Novatronic XV 80/70 70 319 H: 1345 W: 1405 D: 1116 1092 1480
Novatronic XV 80/80 80 319 H: 1345 W: 1405 D: 1116 1092 1480

Log firing system Novatronic XV

inhaltsbild

The log boiler has the following impressive features:

  1. Filling cover in ideal position and with an optimum cross-section for stoking.
  2. Front grate door for simple igniting and convenient de-ashing through the large opening
  3. Generously designed filling chamber for guaranteed optimum infeed, also with difficult fuels
  4. High heat resistance step/slide grate for maintaining the firebed and de-ashing
  5. Lower combustion system with special secondary air injection in the flame channel
  6. Underpressure measuring sensor for optimised combustion in partial load operation
  7. Primary and secondary slide valves for consistent underpressure control of the combustion air volume
  8. Highly resistant lined combustion chamber guarantees low emissions
  9. Vertical heat exchanger tubes enable extremely simple cleaning, either manual or automatic
  10. Lambda probe and flue gas sensor
  11. Energy-efficient and speed-controlled EC flue gas fan
  12. Manual or automatic heat exchanger cleaning mechanism
  13. Maximum efficiency guaranteed with 100 mm all-round insulation
  14. Feed and return line
  15. Boiler control with 5’’ real glass touch display
  16. Ignition blower for automatic ignition

The new generation Zyklotronic XV

inhaltsbild

Fuel: Wood log
Zyklotronic XV: Wood logs 1/2 m

Boiler type Nominal
capacity 

in kW.
Filling
chamber 

in L.
Dimensions 
in mm.
Filling edge 
height in mm
Weight 
in kG
Zyklotronic XV 30/20 20 165 H: 1530 W: 915 D: 920 930 623
Zyklotronic XV 30/25 25 165 H: 1530 W: 915 D: 920 930 623
Zyklotronic XV 30/30 30 165 H: 1530 W: 915 D: 920 930 623

 

Log firing system Zyklotronic XV

inhaltsbild

The log boiler has the following impressive features:

  1. Boiler control with 5’’ real glass touch display
  2. Self-adjusting, operator-friendly filling door, can be hinged on
    either side
  3. Carbonisation gas extraction prevents smoke discharge during
    stoking
  4. Step grate made of a highly heat resistant special casting
  5. Self-adjusting grate door for simple ignition and convenient
    de-ashing
  6. Automatic ignition (optional)
  7. Cyclone-type, vertical vortex combustion chamber for positive,
    optimised burnout
  8. Manual cleaning lever (fully automatic option)
  9. Flue gas fan, can be positioned either on the right or at the
    rear
  10. Lambda sensor with flue gas sensor
  11. Integrated ash tray
  12. Connection for return line elevation
  13. Primary and secondary air control motor

The new generation Easytronic XV

inhaltsbild

Fuel: Wood log
Easytronic XV: Wood logs 1/2 m

Boiler type Nominal
capacity 

in kW.
Filling
chamber 

in L.
Dimensions 
in mm.
Filling edge 
height in mm
Weight 
in kG
Easytronic XV 30/15 12-15 155 H: 1580 W: 655 D: 1080 882 615
Easytronic XV 30/20 12-20 155 H: 1580 W: 655 D: 1080 882 615
Easytronic XV 30/25 15-25 155 H: 1580 W: 655 D: 1080 882 615
Easytronic XV 30/30 15-30 155 H: 1580 W: 655 D: 1080 882 615

 

Log firing system Easytronic XV

inhaltsbild

The log boiler has the following impressive features:

  1. Boiler control with 5’’ real glass touch display
  2. Carbonisation gas extraction with heating flap
  3. Self-adjusting, operator-friendly filling door, can be hinged
    on either side
  4. Filling chamber with steel panel cladding
  5. Primary air supply
  6. Two-part combustion nozzle
  7. Primary air control motor
  8. Secondary air control motor
  9. Integrated ash tray
  10. Cleaning system in the heat exchanger
  11. Manual cleaning lever (fully automatic option)
  12. Water-cooled secondary combustion chamber
  13. Lambda sensor with flue gas sensor
  14. Connection for return line elevation
  15. Automatic ignition (optional)

Nach oben